Products -> EZTest® Self-Contained Biological Indicator

 

EZTest is a self-contained biological indicator for monitoring steam / flash steam, ethylene oxide, hydrogen peroxide, or propylene oxide sterilization. EZTest contains bacterial spores on a filter-paper carrier packaged within a small, thermoplastic culture tube. Inside the thermoplastic culture tube is a sealed-glass ampoule of specially-formulated soybean casein digest culture medium containing a color indicator which turns a dramatic yellow when spores grow. EZTest is easy-to-use and produces visual results within 24 hours (steam, hydrogen peroxide, or propylene oxide) or 48 hours (ethylene oxide) without laboratory transfers.

Announcing EZTest® for Propylene Oxide!

SGM Biotech, Inc. is pleased to announce the release of its EZTest® propylene oxide (PPO) self-contained biological indicator (SCBI) for use in monitoring and validating propylene oxide gas pasteurization of almonds, nuts and other dry food products. The Almond Board of California Food Safety document "Almond Pasteurization Using Propylene Oxide (PPO) Standard Operating Procedure (SOP)" indicates that a process that kills this level of G. stearothermophilus spores equates to a five (5) log reduction of Salmonella.

Availability

EZTest Steam / Flash
Spore Incubation Population Units Reorder #
G. stearothermophilus 24 Hours at
55-60°C
105 100 EZS/5
105 25 EZS/525
106 100 EZS/6
106 25 EZS/625

Smart-Read EZTest Biological Indicator Monitoring System

EZTest Gas (for Ethylene Oxide)
Spore Incubation Population Units Reorder #
B. atrophaeus 48 Hours at
35-39°C
106 100 EZG/6
25 EZG/625
EZTest H2O2 (for Hydrogen Peroxide)
Spore Incubation Population Units Reorder #
G. stearothermophilus 24 Hours at
55-60°C
105 100 EZH/5
106 EZH/6
EZTest PPO (for Propylene Oxide Gas)
Spore Incubation Population Units Reorder #
G. stearothermophilus 24 Hours at
55-60°C
105 100 EZP/5

Use

Please follow instructions provided with each box of EZTest biological indicators.

  1. Place the EZTest biological indicator in a horizontal position in the most difficult to sterilize location of the load.
  2. For Flash cycles, articles should be unwrapped.
  3. Place a sufficient number of EZTest biological indicators throughout the load to be sterilized. NOTE: This number will vary depending on the regulations being met but never less than two is recommended. Ten units per cycle is commonly used.
  4. Expose the load to the sterilization cycle.
  5. After sterilizing, send test units to the test laboratory along with at least one non- sterilized unit marked POSITIVE CONTROL.
  6. Following exposure, remove the EZTest biological indicators as soon as the load cools or has been aerated.
  7. Crush the glass culture medium ampoule using a SGM crusher to activate the culture system.
  8. Place in appropriate incubator. EZTest Steam, H2O2 or PPO: 24 hours at 55-60°C.
    EZTest Gas: 48 hours at 35-39°C.
  9. If the spores survive the sterilization cycle, the culture medium will turn to yellow (positive).
  10. If the spores have been killed, the culture medium will remain the original color (red - ethylene oxide; purple - steam, H2O2 or PPO).
  11. It is best to read results approximately every 12 to 24 hours.
  12. All positive (yellow) samples should be recorded and discarded immediately. All yellow samples should be autoclaved prior to disposal.

Storage

Room temperature.

Expiration

24 months from date of manufacture.

Certification

EZTest biological indicators are traceable to a recognized culture collection and certified for population, D-value, Z-value and performance.

EZTest biological indicator
EZTest Logo
Product Highlights

FDA Approved (steam and EO)

24 hour results for steam, H2O2 or PPO

48 hour results for EO

Easy to Culture

No Laboratory Required

Dramatic Color Change

Related Products

Smart-Read EZTest Biological Indicator Monitoring System offers faster biological results and automated documentation.

Incubator for EZTest biological indicators

EZTest® Test Pack process challenge devices for ethylene oxide or steam featuring EZTest biological indicators

Releasat® rapid readout culturing kit for ethylene oxide featuring SGMStrip biological indicators

SGMStrip™ conventional paper strip biological indicators for steam and ethylene oxide

Purchase

Purchase SGM Biotech Products

EZTest Documents

Material Safety Data Sheets
Technical Reports
Sample Certificates
Product Manuals
Spore News
Technical Papers
Technical Data Sheets

Top EZTest FAQs

At what temperatures does SGM perform D-value studies on EZTest steam?

I sent biological indicators out for a third party verification of the D-value and the results were greater than +/- 20% of the stated value on the Certificate of Analysis. Does this mean I have to reject this lot of product?

My EZTest steam biological indicator was positive. I expected it to be killed. What’s wrong with this biological indicator?

The end of the incubation period for my biological indicators falls on the weekend.  Can I skip that reading and score the units on the next business day?

Copyright 2005, SGM Biotech, Inc. All rights reserved.

SGM Biotech, Inc.
10 Evergreen Drive Suite E
Bozeman, MT 59718 USA
Phone: 406-585-9535
FAX: 406-585-9219
General Information: info@sgmbiotech.com
Customer Service: cust-service@sgmbiotech.com

Valid XHTML 1.1 Valid CSS!